Reference Guide

VLT0305
Message CPU arg1 arg2 voltage is within range.
Arguments arg1 = number, arg2 = name
Detailed
Description
None
Recommended
Response
Action
No response action is required.
Category System Health (VLT = Voltage)
Severity Severity 3 (Informational)
Trap/EventID 2171
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
VLT400
Message The arg1 sensor has failed with a value arg2 Volts.
Arguments arg1 = sensor name, arg2 = voltage
Detailed
Description
A voltage sensor identified in the message may have failed. This condition can
cause system performance issues and degradation in the moitoring capability of
the system.
Recommended
Response
Action
Do one of the following to resolve the issue: 1) Verify the Embedded System
Management (ESM) Log for any sensor related faults. If there is a failed sensor,
replace the system board. 2) Re-configure the system to a minimum configuration,
and verify if the sensor displays a normal value, otherwise replace the system
board. 3) If the sensor identified is a processor voltage sensor, remove the
processor module and inspect processor socket, and replace if required. If the
issue persists, contact your service provider.
Category System Health (VLT = Voltage)
Severity Severity 1 (Critical)
OMSA Event ID 5150
2383