Message CPU arg1 arg2 voltage is greater than the upper warning threshold.
Arguments arg1 = number, arg2 = name
Detailed
Description
High voltages may be the result of problem with the voltage regulator or a problem
with the processor. Elevated voltages may result in damage to the processor or
other electronic components inside the system.
Recommended
Response
Action
1) Turn system off and remove input power for one minute. Re-apply input power
and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue
still persists, contact technical support. Refer to the product documentation to
choose a convenient contact method.
Category System Health (VLT = Voltage)
Severity Severity 2 (Warning)
Trap/EventID 2170
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔ ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔ ✔ ✔ ✔
CMC
VLT0303
Message CPU arg1 arg2 voltage is greater than the upper critical threshold.
Arguments arg1 = number, arg2 = name
Detailed
Description
High voltages may be the result of problem with the voltage regulator or a problem
with the processor. Elevated voltages may result in damage to the processor or
other system electrical components. The system may power down.
Recommended
Response
Action
1) Turn system off and remove input power for one minute. Re-apply input power
and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue
still persists, contact technical support. Refer to the product documentation to
choose a convenient contact method.