Reference Guide
Trap/EventID 2170
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔ ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔ ✔ ✔ ✔
CMC
VLT0225
Message The memory module arg1 voltage is less than the lower critical threshold.
Arguments arg1 = name
Detailed
Description
System hardware detected an over voltage or under voltage condition. If multiple
voltage exceptions occur consecutively the system may power down in failsafe
mode.
Recommended
Response
Action
1) Review system logs for power supply exceptions. 2) Reseat the memory module.
3) If the problem persists, contact technical support. Refer to the product
documentation to choose a convenient contact method.
Category System Health (VLT = Voltage)
Severity Severity 1 (Critical)
Trap/EventID 2169
LCD Message Memory module <name> voltage is outside of range. Contact support
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔ ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔ ✔ ✔ ✔
CMC
VLT0226
Message The memory module arg1 voltage is greater than the upper warning threshold.
Arguments arg1 = name