Reference Guide

LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
BAT1025
Message arg1 is unable to recover cached data from the Battery Backup Unit (BBU).
Arguments arg1 = controller name
Detailed
Description
The controller was unable to recover data from the cache. This may indicate data
loss has occurred.
Recommended
Response
Action
Verify that the battery is charged and in good health. See the hardware
documentation for more information. When the battery charge is unacceptably
low, the battery cannot maintain cached data. Data loss may also have occurred,
restoring data from backups may be needed. Verify whether the battery has met its
recharge limit. The battery may need to be recharged. Contact technical support if
the issue persists.
Category Storage (BAT = Battery Event)
Severity Severity 1 (Critical)
Trap/EventID 4273
OMSA Event ID 2337
OMSA Trap ID 115400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
BAT1026
Message The arg1 has recovered cached data from the Battery Backup Unit (BBU).
Arguments arg1 = controller name
Detailed
Description
The controller has retrieved cached data.
237