Reference Guide
Arguments arg1 = name
Detailed
Description
None
Recommended
Response
Action
No response action is required.
Category System Health (VLT = Voltage)
Severity Severity 3 (Informational)
Trap/EventID 2171
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔ ✔ ✔ ✔
CMC ✔ ✔ ✔ ✔
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔* ✔*
VLT0206
Message The memory module arg1 arg2 voltage is less than the lower warning threshold.
Arguments arg1 = number, arg2 = name
Detailed
Description
System hardware detected an over voltage or under voltage condition. If multiple
voltage exceptions occur consecutively the system may power down in failsafe
mode.
Recommended
Response
Action
1) Review system logs for power supply exceptions. 2) Reseat the memory module.
3) If the problem persists, contact technical support. Refer to the product
documentation to choose a convenient contact method.
Category System Health (VLT = Voltage)
Severity Severity 2 (Warning)
Trap/EventID 2170
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔ ✔ ✔ ✔
CMC
2361