Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔ ✔ ✔ ✔
CMC
VLT0105
Message Processor module arg1 voltage is within range.
Arguments arg1 = name
Detailed
Description
None
Recommended
Response
Action
No response action is required.
Category System Health (VLT = Voltage)
Severity Severity 3 (Informational)
Trap/EventID 2171
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔ ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC
VLT0200
Message The system board arg1 voltage is less than the lower warning threshold.
Arguments arg1 = name
Detailed
Description
System hardware detected an over voltage or under voltage condition. If multiple
voltage exceptions occur consecutively the system may power down in failsafe
mode.
Recommended
Response
Action
1) Review system logs for power supply exceptions 2) Reduce system to minimum
configuration, inspect and re-install system cables. 3) If the problem persists,
contact technical support. Refer to the product documentation to choose a
convenient contact method.
Category System Health (VLT = Voltage)
2357