Reference Guide
VLT Event Messages
VLT0100
Message Processor module arg1 voltage is less than the lower warning threshold.
Arguments arg1 = name
Detailed
Description
System hardware detected an over voltage or under voltage condition. If multiple
voltage exceptions occur consecutively the system may power down in failsafe
mode.
Recommended
Response
Action
1) Review system logs for power supply exceptions. 2) Remove the processor
module. Inspect processor socket for bent pins. 3) If the problem persists, contact
technical support. Refer to the product documentation to choose a convenient
contact method.
Category System Health (VLT = Voltage)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
VLT0101
Message Processor module arg1 voltage is less than the lower critical threshold.
Arguments arg1 = name
Detailed
Description
System hardware detected an over voltage or under voltage condition. If multiple
voltage exceptions occur consecutively the system may power down in failsafe
mode.
Recommended
Response
Action
1) Review system logs for power supply exceptions. 2) Remove the processor
module. Inspect processor socket for bent pins. 3) If the problem persists, contact
technical support. Refer to the product documentation to choose a convenient
contact method.
Category System Health (VLT = Voltage)
Severity Severity 1 (Critical)
LCD Message Processor module <name> voltage is outside of range. Contact support
2354