Reference Guide

VFL0009
Message vFlash media is currently in use by another operation.
Detailed
Description
Unable to access the vFlash media, because another operation is currently using
the vFlash media.
Recommended
Response
Action
Wait until the vFlash media is available for the requested operation, and then retry
the operation.
Category System Health (VFL = vFlash Event)
Severity Severity 2 (Warning)
No alerts are applicable for this message
VFL0010
Message An operation is in progress on the SD card.
Detailed
Description
Another operation is currently in progress on the SD card.
Recommended
Response
Action
Wait untill the current operation is completed, and then retry the requested
operation.
Category System Health (VFL = vFlash Event)
Severity Severity 3 (Informational)
No alerts are applicable for this message
VFL0011
Message vFlash media is not disabled.
Detailed
Description
The vFlash media is not disabled.
Recommended
Response
Action
Disable the vFlash media by running the command racadm set
idrac.vFlashSD.Enable 0.
Category System Health (VFL = vFlash Event)
Severity Severity 3 (Informational)
No alerts are applicable for this message
2334