Reference Guide

LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
VDR55
Message arg1 initialization has failed.
Arguments arg1 = VD Name
Detailed
Description
The controller cannot communicate with attached devices. A disk may be removed
or contain errors. Cables may also be loose or defective.
Recommended
Response
Action
Verify the health of attached devices. Review the Alert Log for significant events.
Make sure the cables are attached securely. See the Cables Attached Correctly
section for more information on checking the cables.
Category Storage (VDR = Virtual Disk)
Severity Severity 1 (Critical)
Trap/EventID 4353
OMSA Event ID 2345
OMSA Trap ID 120400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC *
VDR56
Message Redundancy of arg1 has been degraded.
Arguments arg1 = virtual disk
Detailed
Description
This message occurs when a physical disk in the disk group was removed or when
a physical disk included in a redundant virtual disk fails. Because the virtual disk is
redundant (uses mirrored or parity information) and only one physical disk has
failed, the virtual disk can be rebuilt. Typically, the virtual disk (E.g. RAID 6) has
multiple redundant disks and there is a problem with one of them.
2301