Reference Guide
Recommended
Response
Action
Review other messages to identify whether the physical disk that has errors. If the
virtual disk is redundant, you can replace the physical disk and continue using the
virtual disk. If the virtual disk is non-redundant, you need to recreate the virtual disk
after replacing the physical disk. After replacing the physical disk, run a consistency
check to verify the data.
Category Storage (VDR = Virtual Disk)
Severity Severity 1 (Critical)
Trap/EventID 4353
OMSA Event ID 2340
OMSA Trap ID 120400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC ✔ ✔* ✔ ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔ ✔*
VDR51
Message The consistency check process made corrections and completed on arg1 .
Arguments arg1 = virtual disk
Detailed
Description
The consistency check completed on the virtual disk after making corrections.
Recommended
Response
Action
No response action is required.
Category Storage (VDR = Virtual Disk)
Severity Severity 3 (Informational)
Trap/EventID 4355
OMSA Event ID 2341
OMSA Trap ID 120100
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC ✔ ✔* ✔ ✔*
2298