Reference Guide
Category Storage (VDR = Virtual Disk)
Severity Severity 3 (Informational)
Trap/EventID 4355
OMSA Event ID 2281
OMSA Trap ID 120100
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC ✔ ✔* ✔ ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔ ✔* ✔*
VDR49
Message arg1 is permanently degraded.
Arguments arg1 = VD Name
Detailed
Description
A redundant virtual disk has lost redundancy. This may occur when the virtual disk
suffers the failure of more than one physical disk. In this case, both the source
physical disk and the target disk with redundant data have failed. A rebuild is not
possible because there is no longer redundancy.
Recommended
Response
Action
Replace the failed disks and restore from backup.
Category Storage (VDR = Virtual Disk)
Severity Severity 1 (Critical)
Trap/EventID 4353
OMSA Event ID 2310
OMSA Trap ID 120400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC ✔ ✔* ✔ ✔*
2296