Reference Guide

LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
VDR31
Message Controller cache is preserved for missing or offline arg1 .
Arguments arg1 = VD Name
Detailed
Description
The controller is getting disconnected from its virtual disk, while Input Output (IO)
is in-progress.
Recommended
Response
Action
Try importing foreign disks, if any. Check if the enclosure containing the Virtual
Disk is disconnected from the controller. Insert any disks that are reported missing
or failed. If the enclosure or disks were removed intentionally, the preserved cache
can be discarded. See storage hardware documentation for more information on
performing these steps.
Category Storage (VDR = Virtual Disk)
Severity Severity 2 (Warning)
Trap/EventID 4354
OMSA Event ID 2125
OMSA Trap ID 120300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
VDR32
Message Background initialization has started for arg1 .
Arguments arg1 = virtual disk
Detailed
Description
Background initialization of a virtual disk has started. This is an automated process
that writes the parity or mirror data on newly created virtual disks.
2284