Reference Guide
OMSA Trap ID 120100
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC ✔ ✔* ✔ ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔ ✔* ✔*
VDR16
Message Consistency check of arg1 failed.
Arguments arg1 = virtual disk
Detailed
Description
A physical disk included in the virtual disk failed or there is an error in the parity
information. A failed physical disk causes errors in parity information.
Recommended
Response
Action
Check that all the physical disks of the virtual disk are in a healthy condition.
Replace any disks that are not healthy and restart the operation. If this is not the
problem, delete the virtual disk and restore the data to the disk from a backup
copy.
Category Storage (VDR = Virtual Disk)
Severity Severity 1 (Critical)
Trap/EventID 4353
OMSA Event ID 2076
OMSA Trap ID 120400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC ✔ ✔* ✔ ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔ ✔* ✔*
VDR17
Message arg1 format failed.
2273