Reference Guide

OMSA Trap ID 115100
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
BAT1008
Message Write policy on arg1 was changed to Write Through.
Arguments arg1 = controller name
Detailed
Description
The controller battery cannot maintain cached data for the required period of time.
For example, if the required period of time is 24 hours, then the battery cannot
maintain cached data for 24 hours.
Recommended
Response
Action
Verify the battery health is good. See the storage hardware documentation to verify
battery health. Contact technical support.
Category Storage (BAT = Battery Event)
Severity Severity 2 (Warning)
Trap/EventID 4274
OMSA Event ID 2188
OMSA Trap ID 115300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
BAT1009
Message Write policy on arg1 was changed to Write Back.
226