Reference Guide

Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
UEFI0240
Message An error occurred during Voltage Regulator (VR) initialization on memory riser
arg1 .
Arguments arg1 = riser letter
Detailed
Description
An error occurred during Memory Voltage Regulator initialization during the VR0
SVID Ramp phase.
Recommended
Response
Action
Do the following: 1) Remove input power to the system, 2) Reseat the memory riser
and 3) Restart the system. For more information, see the platform Owners Manual.
Category System Health (UEFI = UEFI Event)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
UEFI0241
Message An error occurred during Voltage Regulator (VR) initialization on memory riser
arg1 .
Arguments arg1 = riser letter
Detailed
Description
An error occurred during Memory Voltage Regulator initialization during the VR1
SVID Ramp phase.
2213