Reference Guide
BAT1000
Message Battery on arg1 is missing.
Arguments arg1 = controller name
Detailed
Description
The controller cannot communicate with the battery. The battery is absent or
improperly connected. A battery with a weak or depleted charge may also cause
this message.
Recommended
Response
Action
Verify that the device is present and then check the cables. See the storage
hardware documentation to verify cabling. In addition check the connection to the
controller battery and the battery health. A battery with a weak or depleted charge
may cause this message.
Category Storage (BAT = Battery Event)
Severity Severity 2 (Warning)
Trap/EventID 4274
OMSA Event ID 2264
OMSA Trap ID 75300;80300;85300;90300;95300;100300;105300;110300;115300;120300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC ✔ ✔* ✔ ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔ ✔* ✔*
BAT1001
Message Battery on arg1 was replaced.
Arguments arg1 = controller name
Detailed
Description
A controllers battery was replaced.
Recommended
Response
Action
No response action is required.
Category Storage (BAT = Battery Event)
Severity Severity 3 (Informational)
Trap/EventID 4275
221