Reference Guide
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔ ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC
BAT0014
Message The storage battery for disk drive bay arg1 is absent.
Arguments arg1 = bay
Detailed
Description
The PERC RAID controller battery may report absent due to disconnect or thermal
exceptions.
Recommended
Response
Action
1) Verify the PERC RAID controller battery installation for the associated bay. 2) If
installed, reseat or reconnect the battery and cables. 3) Check the system logs for
thermal related issues.
Category System Health (BAT = Battery Event)
Severity Severity 1 (Critical)
Trap/EventID 2225
LCD Message Battery for disk drive bay <bay> is absent. Check battery.
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔ ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔ ✔ ✔ ✔
CMC
BAT0015
Message The arg1 battery is low.
Arguments arg1 = name
Detailed
Description
System settings may be preserved if input power is not removed from the power
supplies.
216