Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
UEFI0110
Message One or more memory errors have occurred on memory slot: arg1 .
Arguments arg1 = slot
Detailed
Description
One or more memory errors have occurred on memory slot identified in the
message. The error occurred during Write DQ/DQS initialization.
Recommended
Response
Action
Remove input power to the system, reseat the DIMM module and restart the
system. If the issues persist, then replace the faulty memory module identified in
the message.
Category System Health (UEFI = UEFI Event)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
UEFI0111
Message One or more memory errors have occurred on memory slot: arg1 .
Arguments arg1 = slot
Detailed
Description
One or more memory errors have occurred on memory slot identified in the
message. The error occurred during memory test.
Recommended
Response
Action
Remove input power to the system, reseat the DIMM module and restart the
system. If the issues persist, then replace the faulty memory module identified in
the message.
Category System Health (UEFI = UEFI Event)
Severity Severity 1 (Critical)
2140