Reference Guide
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔ ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC
BAT0009
Message The storage battery is absent.
Detailed
Description
The PERC RAID controller battery may report absent due to disconnect or thermal
exceptions.
Recommended
Response
Action
1) Verify the PERC RAID controller battery installation. 2) If installed, reseat or
reconnect the battery and cables. 3) Check the system logs for thermal related
issues.
Category System Health (BAT = Battery Event)
Severity Severity 1 (Critical)
Trap/EventID 2225
LCD Message Storage battery is absent. Check battery.
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔ ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔ ✔ ✔ ✔
CMC
BAT0010
Message The storage battery for disk drive bay arg1 is low.
Arguments arg1 = bay
Detailed
Description
The system has to remain powered on to charge the battery.
213