Reference Guide
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
UEFI0085
Message One or more chipset errors have occurred.
Detailed
Description
One or more chipset errors have occurred.
Recommended
Response
Action
Check the System Event Log (SEL) to identify the chipset error. Do one of the
following: 1) Turn off the input power to the system and turn on again. 2) Update
the PCIe device firmware. If the issue persists, contact your service provider.
Category System Health (UEFI = UEFI Event)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
UEFI0086
Message Unsupported Small Outline Dual In-line Memory Module (SODIMM) memory is
installed on RDIMM memory slot: arg1 .
Arguments arg1 = slot number
Detailed
Description
Unsupported Small Outline Dual In-line Memory Module (SODIMM) memory is
installed on the RDIMM memory slot indentified in the message.
Recommended
Response
Action
Remove the unsupported SODIMM module from the identified memory slot and
replace it with a supported module. For more information, see the platform
Owners Manual.
2126