Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
UEFI0079
Message One or more Uncorrectable Memory errors occurred in the previous boot.
Detailed
Description
One or more Uncorrectable Memory errors occurred in the previous boot.
Recommended
Response
Action
Check the System Event Log (SEL) to identify the non-functional DIMM, and then
replace the DIMM.
Category System Health (UEFI = UEFI Event)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
UEFI0080
Message PCIe link speed is not optimal for arg1 . Expected link speed: Gen arg2 and actual
link speed: Gen arg3 .
Arguments arg1 = PCIe device, arg2 = generation number, arg3 = generation number
Detailed
Description
The PCIe link speed is not optimal for the identified PCIe device.
Recommended
Response
Action
Do one of the following: 1) Turn off the input power to the system and turn on
again. 2) Update the PCIe device firmware. If the issue persists, contact your service
provider.
Category System Health (UEFI = UEFI Event)
Severity Severity 2 (Warning)