Reference Guide
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
UEFI0036
Message Unable to initialize the iDRAC Shared Memory Architecture (SMA) interface.
Detailed
Description
The iDRAC Shared Memory Architecture (SMA) interface cannot be initialized. The
BIOS will use the Keyboard Controller Style (KCS) interface.
Recommended
Response
Action
Do one of the following: 1) Remove input power from the system, wait for 30
seconds, and re-apply input power. Turn on the system. 2) Update the iDRAC
firmware on the system.
Category System Health (UEFI = UEFI Event)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
UEFI0037
Message Unable to communicate with iDRAC because of an issue in the iDRAC Shared
Memory Architecture (SMA) Intelligent Platform Management Interface (IPMI).
Detailed
Description
Unable to communicate with iDRAC because of an issue in the iDRAC Shared
Memory Architecture (SMA) Intelligent Platform Management Interface (IPMI).
Continuing to boot may result in unexpected power loss because of unknown
power inventory and unavailability of features such as active power management,
thermal management.
2099