Reference Guide
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
UEFI0014
Message CPU Exception Type 0x11: Alignment Check (Software).
Detailed
Description
A CPU alignment check exception (type 0x11) occurred in the pre-boot UEFI
environment.
Recommended
Response
Action
Recently installed hardware or updated software may cause this exception. Update
or remove the hardware or software.
Category System Health (UEFI = UEFI Event)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
UEFI0015
Message Lifecycle Controller (LC) firmware was not accessible and is therefore in Recovery
mode.
Detailed
Description
The BIOS is unable to access the Lifecycle Controller firmware. No Lifecycle
Controller functionality is available while in Recovery Mode.
Recommended
Response
Action
Perform the following actions: 1)Reboot the system. 2) Press F2 during boot to
enter System Setup. 3) Select iDRAC Settings then Lifecycle Controller. 4) Change
Lifecycle Controller back to Enabled. If subsequent failures occur, press and hold
the system ID button down for 15 seconds to reset the iDRAC. For more
information on how to reset iDRAC, see iDRAC Users Guide.
2087