Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
UEFI0004
Message CPU Exception Type 0x06: Invalid Opcode (Software).
Detailed
Description
A CPU invalid opcode exception (type 0x06) occurred in the pre-boot UEFI
environment. The software attempted to execute invalid code.
Recommended
Response
Action
Recently installed hardware or updated software may cause this exception. Update
or remove the hardware or software.
Category System Health (UEFI = UEFI Event)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
UEFI0005
Message CPU Exception Type 0x07: Math Coprocessor Not Available (Hardware).
Detailed
Description
A CPU math coprocessor not available (type 0x07) exception occurred in the pre-
boot UEFI environment.
Recommended
Response
Action
Recently installed hardware or updated software may cause this exception. Update
or remove the hardware or software.
Category System Health (UEFI = UEFI Event)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
2082