Reference Guide

Recommended
Response
Action
Check the chassis event log for fan issues and fix any issues present. If no fan issues
are detected, check chassis ambient temperature and make sure the temperature is
within operating range. Utilize the RACADM command "racadm getsensorinfo" to
check the chassis ambient temperature.
Category Audit (TMP = Temperature)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
TMP8501
Message Unable to read planar board temperature sensors. The cooling has been increased
to safeguard the system.
Detailed
Description
System was unable to read planar board or control panel temperature sensors. The
fan speed was increased to protect system hardware.
Recommended
Response
Action
Remove AC power from the system and reapply AC power. Check to see if the
issue is resolved. If the issue persists, contact your service provider.
Category Audit (TMP = Temperature)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
TMP8502
Message Able to read planar board temperature sensors. Cooling set for normal chassis
operation.