Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
TMP502
Message The arg1 sensor has returned to a normal state with a value of arg2 degrees
Celsius.
Arguments arg1 = sensor name, arg2 = temperature
Detailed
Description
The sensor identified in the message has returned to a normal state.
Recommended
Response
Action
No response action is required.
Category System Health (TMP = Temperature)
Severity Severity 3 (Informational)
OMSA Event ID 5052
OMSA Trap ID 5052
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔* ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
TMP503
Message The arg1 sensor state has changed to a warning state with a value of arg2 degrees
Celsius.
Arguments arg1 = sensor name, arg2 = temperature
Detailed
Description
The temperature sensor identified in the message is faulty, or the temperature
exceeds the warning threshold. This condition can cause system performance
issues and degradation in the moitoring capability of the system.
Recommended
Response
Action
Verify the Embedded System Management (ESM) Log for any sensor related faults.
If there is a failed sensor, replace the system board. For more information, contact
your service provider. Otherwise, change the warning threshold for the
2069