Reference Guide
Trap/EventID 4210
OMSA Event ID 2101
OMSA Trap ID 105300
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC ✔ ✔* ✔ ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔ ✔*
TMP1002
Message arg1 has exceeded the maximum failure threshold.
Arguments arg1 = tempsensor name
Detailed
Description
The enclosure is too hot. A variety of factors can cause the excessive temperature.
For example, a fan may have failed, the thermostat may be set too high, or the
room temperature may be too hot.
Recommended
Response
Action
Check for factors that may cause overheating. For example, verify that the
enclosure fan is working. You should also check the thermostat settings and
examine whether the enclosure is located near a heat source. Make sure the
enclosure has enough ventilation and that the room temperature is not too hot.
Refer to the enclosure documentation for more diagnostic information.
Category Storage (TMP = Temperature)
Severity Severity 1 (Critical)
Trap/EventID 4209
OMSA Event ID 2102
OMSA Trap ID 105400
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC ✔ ✔* ✔ ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC ✔ ✔*
2065