Reference Guide

TMP0115
Message The arg1 temperature is greater than the upper critical threshold.
Arguments arg1 = name
Detailed
Description
Ambient air temperature is too warm or one or more fans may have failed.
Recommended
Response
Action
Check system operating environment and review event log for fan failures.
Category System Health (TMP = Temperature)
Severity Severity 1 (Critical)
Trap/EventID 2161
LCD Message The <name> temperature is outside of range . Check Fans
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
TMP0116
Message The arg1 temperature is outside of range.
Arguments arg1 = name
Detailed
Description
Ambient air temperature is too warm or cool.
Recommended
Response
Action
Check system operating environment and review event log for fan failures.
Category System Health (TMP = Temperature)
Severity Severity 1 (Critical)
Trap/EventID 2161
LCD Message The <name> temperature is outside of range. Check Fans