Reference Guide
Recommended
Response
Action
Install supported operating system and then retry the operation.
Category System Health (SYS = System Info)
Severity Severity 2 (Warning)
No alerts are applicable for this message
SYS8500
Message Delay Auto-throttle sent to arg1 server(s). arg2 arg3
Arguments arg1 = number of servers, arg2 = error string, arg3 = errors
Detailed
Description
The Chassis Management Controller (CMC) sent messages to delay power
throttling to all capable servers in the chassis. This was done because the CMC
firmware was updated or a failover was inititiated. If specific server errors are
shown in the message, verify that the iDRAC and Lifecycle Controller firmware
versions on those servers is updated to the most current version available.
Recommended
Response
Action
If no errors are shown, no response is required. If errors are listed in the message,
navigate to the named servers and make sure that IDRAC and Lifecycle Controller
firmware versions are the latest available.
Category Audit (SYS = System Info)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC ✔* ✔*