Reference Guide

Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
SYS046
Message Unable to import the system configuration XML file from the network share.
Detailed
Description
An error occurred while copying the system configuration XML file from the
network share.
Recommended
Response
Action
If the file is being copied from an NFS share, make sure that it is accessible from
iDRAC. If the file is being copied from a CIFS share, make sure that it is accessible
from iDRAC using the share credentials provided. Test the network share access
using the Test Network Connection method. For more information, see the
Lifecycle Controller Users Guide.
Category Configuration (SYS = System Info)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
SYS047
Message Input file for system configuration XML is not compliant with configuration
schema.
Detailed
Description
The input file is not compliant with the system configuration XML schema.
Recommended
Response
Action
Make sure that the input file is compliant with the system configuration schema
published on delltechcenter.com/lc in the LC XML Schema Guide.
1966