Reference Guide

SWU8556
Message Unable to configure the sled network uplink on sled arg1 .
Arguments arg1 = slot number
Detailed
Description
The sled network uplink on the sled identified in the message could not be
configured. The servers on the sled may not have expected network connectivity.
Recommended
Response
Action
Perform a Virtual Reseat operation, and then retry the operation. To virtually reseat
a server 1) Using the CMC Web UI, go to Chassis Overview > Troubleshooting >
Reset Components, and then select slot for the component identified in the
message and apply the Virtual Reseat or 2) Run the following RACADM command
at the command line interface: "racadm serveraction -f -m sled-<slot number>
reseat".
Category Audit (SWU = Software Change)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
SWU8557
Message Invalid firmware: The uploaded firmware image does not contain a verification
signature.
Detailed
Description
Invalid firmware: The uploaded firmware image does not contain a verification
signature.
Recommended
Response
Action
Use a valid firmware image and retry the operation.
Category Audit (SWU = Software Change)
Severity Severity 2 (Warning)
No alerts are applicable for this message
1945