Reference Guide
Category Configuration (BAR = Backup/Restore)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
BAR092
Message Disconnect from NFS unsuccessful.
Detailed
Description
The attempt to disconnect from the specified NFS location was not successful.
Recommended
Response
Action
If this happens on a backup request, restart the Integrated Remote Access
Controller and try the operation again. If this is a restore request the Integrated
Remote Access will be restarted during the execution of the request. Only restart
the Integrated Remote Access Controller if it does not restart on its own.
Category Configuration (BAR = Backup/Restore)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
BAR093
Message Disconnect from CIFS unsuccessful.
Detailed
Description
The attempt to disconnect from the specified CIFS location was not successful.
193