Reference Guide
SWU8524
Message Unable to update the iDRAC on the server in slot arg1 firmware: ErrorCode=0x
arg2 .
Arguments arg1 = slot number, arg2 = error no
Detailed
Description
The firmware update operation is not successful. This may be due to a problem
encountered by the firmware, or because a server was removed during the
firmware update operation.
Recommended
Response
Action
Reacquire the Image file from the source folder, and then retry the operation.
Category Updates (SWU = Software Change)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC ✔* ✔*
SWU8525
Message Unable to update the iDRAC firmware on the server in slot arg1 . The firmware
update timeout limit is exceeded.
Arguments arg1 = slot number
Detailed
Description
The firmware update operation is not successful. The update process was not
completed within the firmware update timeout duration.
Recommended
Response
Action
Retry the operation. If the issue persists, contact your service provider.
Category Updates (SWU = Software Change)
Severity Severity 2 (Warning)
1928