Reference Guide

Detailed
Description
The remote network share settings are accessible on the CMC web interface at
Server Overview/Setup/Remote Network Share tab. These settings must be correct
for the CMC to connect to the remote network share and perform the application
of the profile as specified in the Quick Deploy tab on the Profiles page.
Recommended
Response
Action
Make sure that the remote network share settings in the CMC are correct and that
the remote share NFS/CIFS server is functioning correctly. Use the "Test Network"
button in the CMC Web interface to make sure that the CMC can access the
remote share.
Category Configuration (SWC = Software Config)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
SWC8623
Message Unable to save the I/O Aggregator configuration in arg1 .
Arguments arg1 = slot id
Detailed
Description
The current configuration details of IOA in the slot identified in the message could
not be saved to its startup configuration.
Recommended
Response
Action
Power-cycle the IOA and retry the operation.
Category Configuration (SWC = Software Config)
Severity Severity 2 (Warning)
Trap/EventID 10530
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * * *
1915