Reference Guide

Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
SWC8531
Message Chassis Management Controller unable to set iDRAC administrator role for root
user account.
Detailed
Description
The Chassis Management Controller is unable to set the administrator role for the
iDRAC root user. This can happen if the communication to the iDRAC from CMC is
non-functional or iDRAC is rebooting.
Recommended
Response
Action
If communications with the iDRAC is not functioning, reset the iDRAC and retry the
operation after a few minutes. Run the RACADM command "racadm ping server-
<slot number> " to check the communications. If the communications are not
functional, restart the iDRAC by performing a Virtual Reseat of the server using the
RACADM command "racadm racreset -m server-<slot id>".
Category Audit (SWC = Software Config)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
SWC8532
Message Chassis Management Controller is unable to set chassis assigned QuickDeploy IP
addresses because the starting IP address cannot accommodate all iDRACs.
Detailed
Description
The starting IP address specified cannot accommodate all the servers. The starting
iDRAC IPv4 Address specifies the static IPv4 address of the iDRAC located in the
first slot. The static IPv4 address of each subsequent iDRAC is calculated as a slot
number increment of this IPv4 address.
1895