Reference Guide

SWC8529
Message Chassis Management Controller unable to enable the iDRAC root user.
Detailed
Description
The Chassis Management Controller is unable to enable the iDRAC root user. This
can happen if the communication to the iDRAC from CMC is non-functional or
iDRAC is rebooting
Recommended
Response
Action
If communications with the iDRAC is not functioning, reset the iDRAC and retry the
operation after a few minutes. Run the RACADM command "racadm ping server-
<slot number> " to check the communications. If the communications are not
functional, restart the iDRAC by performing a Virtual Reseat of the server using the
RACADM command "racadm racreset -m server-<slot id>".
Category Audit (SWC = Software Config)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
SWC8530
Message Chassis Management Controller unable to set administrator access to the iDRAC
root user.
Detailed
Description
The Chassis Management Controller is unable to set the server administrator
access to the iDRAC root user. This can happen if the communication to the iDRAC
from CMC is non-functional or the iDRAC is rebooting
Recommended
Response
Action
If communications with the iDRAC is not functioning, reset the iDRAC and retry the
operation after a few minutes. Run the RACADM command "racadm ping server-
<slot number> " to check the communications. If the communications are not
functional, restart the iDRAC by performing a Virtual Reseat of the server using the
RACADM command "racadm racreset -m server-<slot id>".
Category Audit (SWC = Software Config)
Severity Severity 3 (Informational)
1894