Reference Guide

Recommended
Response
Action
Make sure: 1) The login credentials for the operation have user config
administration privilege, 2) The user name given is valid. If the issue persists, restart
the CMC and retry the operation.
Category Audit (SWC = Software Config)
Severity Severity 2 (Warning)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
SWC8521
Message Unable to modify timeout for session: arg1 : arg2 - arg3
Arguments arg1 = SER/TEL/SSH/GUI/RAC/KVM/ERR, arg2 = error code, arg3 = error message
Detailed
Description
Unable to modify the timeout for the session.
Recommended
Response
Action
Make sure: 1) The login credentials for the operation have chassis config
administration privilege, 2) The session timeout given is valid. If the issue persists,
restart the CMC and retry the operation.
Category Audit (SWC = Software Config)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
SWC8522
Message Chassis Group Leader update of member arg1 configuration successful.
1889