Reference Guide
SWC5005
Message Unable to update the System Controller (SC) firmware
Detailed
Description
The System Controller (SC) firmware cannot be updated. For information about the
causes, see SEL Event Data Byte 2.
Recommended
Response
Action
Retry the SC firmware update operation. If the issue persists, try updating by using a
different firmware update file.
Category Updates (SWC = Software Config)
Severity Severity 1 (Critical)
No alerts are applicable for this message
SWC5006
Message System Controller (SC) Firmware Update Successful
Detailed
Description
System Controller (SC) reported a successful Firmware Update
Recommended
Response
Action
No response action required.
Category Updates (SWC = Software Config)
Severity Severity 3 (Informational)
No alerts are applicable for this message
SWC8500
Message Unable to generate Profile with [ arg1 ] settings.
Arguments arg1 = number of entries
Detailed
Description
Unable to communicate with iDRAC.
Recommended
Response
Action
Check if iDRAC is ready and system is running properly. Utilize the RACADM
command by running "racadm getversion" to list all the servers and make sure the
iDRAC version is displayed. If the iDRAC is listed as Not Ready then wait until it
becomes ready. A Virtual Reseat may be required.
Category Configuration (SWC = Software Config)
Severity Severity 1 (Critical)
1877