Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
BAR073
Message Delete of vFlash Backup partition unsuccessful.
Detailed
Description
The operation to delete the vFlash backup partition did not complete successfully.
Recommended
Response
Action
Enable and initialize the vFlash media and retry the export. If the error continues,
try a new vFlash media or use the network share option(s).
Category Configuration (BAR = Backup/Restore)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
BAR074
Message Unable to collect Firmware Inventory information.
Detailed
Description
The collection and export of firmware inventory data did not complete
successfully.
Recommended
Response
Action
Apply the Dell Update Package for Unified Server Configurator (USC). If collect
system inventory on reboot (CSIOR) is not enabled, enter and exit System Services
in USC to update the database, reboot the system and try the operation again. If
the error continues, use the field service repair software to repair the Lifecycle
Controller. Download all Dell Update Packages for USC, Diagnostics Driver Packs,
and device firmware for all host system devices, install all packages and retry the
operation.
Category Configuration (BAR = Backup/Restore)
Severity Severity 1 (Critical)
183