Message Unable to perform RAID operations because the selected controller is in HBA
mode.
Detailed
Description
Unable to perform RAID operations because the selected controller is in HBA
mode.
Recommended
Response
Action
Do one of the following: 1) Retry the operation using other controllers that support
RAID operations and are not in HBA mode. 2) Change the mode of the controller
from HBA mode to RAID mode and retry the operation.
Category Configuration (SWC = Software Config)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC
SWC0076
Message The following iDRAC internal storage partitions present in the system were not
mounted during the system startup: arg1
Arguments arg1 = partitions
Detailed
Description
Lifecycle Controller detected that the iDRAC internal storage partitions identified in
the message were not made available by BIOS during the boot process.
Recommended
Response
Action
No response action required. If the issue occurs consistently during system startup,
restart the iDRAC and then restart the system. If the issue persists, contact your
service provider.
Category Configuration (SWC = Software Config)
Severity Severity 3 (Informational)