Reference Guide

Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
SWC0060
Message Unable to complete the operation.
Detailed
Description
One or more vFlash partitions are attached.
Recommended
Response
Action
Use iDRAC Web interface to detach the vFlash partitions and retry the operation.
Category Configuration (SWC = Software Config)
Severity Severity 1 (Critical)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC
SWC0061
Message Unable to complete the operation.
Detailed
Description
Write-protection is enabled on the vFlash SD card.
Recommended
Response
Action
Remove the write-protection on the vFlash SD card and retry the operation.
Category Configuration (SWC = Software Config)
Severity Severity 1 (Critical)
1782