Reference Guide
No alerts are applicable for this message
STOR304
Message Unable to change controller mode while Virtual Disks and/or Hotspares are present
on the controller.
Detailed
Description
Controller mode cannot be changed as the controller has virtual disk or hotspare
associated with it.
Recommended
Response
Action
Delete the Virtual Disks and/or Hotspares and retry the operation.
Category Configuration (STOR = Storage)
Severity Severity 2 (Warning)
No alerts are applicable for this message
STOR305
Message Unable to change controller mode while there is preserved cache present on the
controller.
Detailed
Description
Controller mode cannot be changed as controller has a preserved cache.
Recommended
Response
Action
Delete the preserved cache and retry the operation.
Category Configuration (STOR = Storage)
Severity Severity 2 (Warning)
No alerts are applicable for this message
STOR306
Message Unable to change controller mode while security key is assigned to the controller.
Detailed
Description
Controller mode cannot be changed as the controller currently has the securtiy
key assigned.
Recommended
Response
Action
Delete the security key and retry the operation.
Category Configuration (STOR = Storage)
Severity Severity 2 (Warning)
No alerts are applicable for this message
1703