Reference Guide
STOR3
Message CEM Storage Management has lost communication with the arg1 .
Arguments arg1 = Controller Name
Detailed
Description
Storage Management has lost communication with a controller. This may occur if
the connectivity between the controller and iDRAC is disrupted or any underlying
hardware problems are encountered.
Recommended
Response
Action
Reboot the system or iDRAC. If the problem is not resolved, contact technical
support.
Category Storage (STOR = Storage)
Severity Severity 1 (Critical)
Trap/EventID 4177
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC ✔ ✔* ✔ ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔*
CMC ✔ ✔*
STOR300
Message Unable to change the controller mode because there are already pending
operations.
Detailed
Description
The requested operation could not be completed because at least one other
pending operation was found on the RAID controller. This operation needs
exclusivity because it requires a server reboot for changes to apply.
Recommended
Response
Action
Do one of the following: 1) Create a job to complete the pending operations, allow
the job to complete, and then retry the operation. 2) Cancel any pending
operations on the RAID controller, and then retry the operation.
Category Configuration (STOR = Storage)
Severity Severity 2 (Warning)
No alerts are applicable for this message
1701