Reference Guide
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔* ✔* ✔* ✔*
CMC ✔ ✔* ✔* ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔*
CMC ✔* ✔* ✔*
STOR17
Message The fault-tolerant pair of RAID controllers arg1 and arg2 can have issues in their
PCIe fabric because both controllers are on the same PCIe fabric.
Arguments arg1 = RAID controller 1, arg2 = RAID controller 2
Detailed
Description
The two RAID controllers are on the same PCIe Fabric. This means that an issue
with a single PCIe switch or Mezzanine card could result in the loss of all storage
functionality from this pair of controllers.
Recommended
Response
Action
Change the slot location of one of the RAID Controllers.
Category Storage (STOR = Storage)
Severity Severity 2 (Warning)
Trap/EventID 4178
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔
CMC ✔ ✔ ✔ ✔*
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC ✔ ✔*
STOR18
Message A Shared Storage device is detected in slots other than Chassis Slots 5 and 6. This
configuration is not currently supported.
Detailed
Description
Utilizing Shared Storage add-in cards outside of slots 5 and 6 is not supported. The
card will be allowed to turn on, however some functionality may be degraded.
1699