Reference Guide

Recommended
Response
Action
Make sure that the newly inserted storage sled has the same number of PERC
controllers as the pervious storage sled so that the new sled will have the same
operation mode after part replacement.
Category Storage (STOR = Storage)
Severity Severity 2 (Warning)
Trap/EventID 4178
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * *
STOR14
Message The peripheral sled in slot arg1 initialization is not complete.
Arguments arg1 = slot number
Detailed
Description
Peripheral sled intinilization is not successful with following possible reasons: 1)
FRU is not functioning. 2) Sled internal components are not responding. 3)
Component power state is not good. 4) Hardware configuration errors.
Recommended
Response
Action
Do the following: 1) Check system log for further information about the issue, 2)
Remove asnd re-insert the peripheral sled identified in the message or virtual reseat
the sled, 3) Reset the CMC and wait for a few minutes for the CMC to finish
restarting. If the issue persists, contact your service provider.
Category Storage (STOR = Storage)
Severity Severity 1 (Critical)
Trap/EventID 4177
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC * * * *
CMC * * *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC * *
CMC * * *
1697