Reference Guide

Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
STOR12
Message Chassis is operating with a disabled RAID controller.
Detailed
Description
One or more RAID controllers is disabled. This prevents Fault Tolerant mode from
operating.
Recommended
Response
Action
No response action is required.
Category Storage (STOR = Storage)
Severity Severity 3 (Informational)
Trap/EventID 4179
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
STOR13
Message Unable to set the operation mode of the newly inserted storage sled in slot arg1 to
Split Single or Split Dural Host, because the storage sled has only one PERC
controller.
Arguments arg1 = slot number
Detailed
Description
The operation mode of the newly inserted storage sled in the slot identified in the
message cannot be set because the storage sled has only one PERC controller. The
operation mode will only be Join after part replacement.
1696