Reference Guide

STOR10
Message Access to shared storage will not be available, because the RAID controller is
unable to turn on.
Detailed
Description
The RAID controller was detected, however it is unable to turn on. Access to
shared storage will not be available.
Recommended
Response
Action
Update the Chassis Infrastructure firmware.
Category Storage (STOR = Storage)
Severity Severity 1 (Critical)
Trap/EventID 4177
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC *
CMC *
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC *
CMC * *
STOR11
Message The currently detected hardware configuration is High Availability Ready. However,
the current software solution does not yet support high availability.
Detailed
Description
The current hardware configuration is setup correctly for High Availability.
However, the current firmware does not provide this functionality and one of the
cards will be kept in a powered down state until High Availability capable firmware
is installed.
Recommended
Response
Action
No response action is required.
Category Storage (STOR = Storage)
Severity Severity 3 (Informational)
Trap/EventID 4179
1695