Reference Guide

configuration and job creation on the next controller. 2) Schedule multiple jobs to
run at a later time using the scheduling options.
Recommended
Response
Action
Make sure that the currently running job is completed, and then retry the
operation. If necessary, recreate the configuration and the job. For information
about running jobs on multiple storage controllers, see the iDRAC Online Help or
iDRAC Users Guide.
Category Configuration (STOR = Storage)
Severity Severity 1 (Critical)
No alerts are applicable for this message
STOR089
Message The storage configuration operation is successfully completed and the change is in
pending state.
Detailed
Description
The storage configuration operation is successfully completed and the change is in
pending state.
Recommended
Response
Action
To apply the configuration operation immediately, create a configuration job using
the --realtime option. To create the necessary real-time job, run the jobqueue
command. For more information about jobqueue command, run the racadm help
jobqueue command.
Category Storage (STOR = Storage)
Severity Severity 3 (Informational)
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
STOR090
Message Unable to create a virtual disk because an invalid combination of span count or
number of disks was entered for the RAID level selected.
Detailed
Description
Unable to create a virtual disk because an invalid combination of span count or
disks passed was entered for the RAID level selected.
Recommended
Response
Action
Enter a span count value (-sc option) or number of disks (-pdkey option) that is
appropriate for the RAID level selected. See the PERC Controller Users Guide for
valid span count and number of disks required for a raid level. Retry the operation
by running the RACADM storage createvd command with the appropriate options.