Reference Guide
Category Configuration (STOR = Storage)
Severity Severity 2 (Warning)
No alerts are applicable for this message
STOR078
Message The requested operation requires a reboot type that does not match the reboot
type required for pending operations.
Detailed
Description
The requested operation cannot be performed because it involves server reboot
type which is different than the reboot type of pending operations. Combining
operations with different reboot types for the same RAID controller is not
supported by iDRAC.
Recommended
Response
Action
Cancel any pending operations on the RAID controller and then retry the
operation.
Category Configuration (STOR = Storage)
Severity Severity 2 (Warning)
No alerts are applicable for this message
STOR079
Message The device does not support this operation or is in a state that does not allow this
operation.
Detailed
Description
The requested operation cannot be performed because it is either not supported
by the device or the device was not in the right state to perform the operation.
Recommended
Response
Action
Make sure the device supports the requested operation. If the operation is
supported, then make sure the server is turned on and retry the operation.
Category Configuration (STOR = Storage)
Severity Severity 2 (Warning)
No alerts are applicable for this message
STOR081
Message The job could not be created because the reboot type selected for the job creation
and the reboot type required for pending operations do not match.
Detailed
Description
The job could not be created because the reboot type selected for the job creation
and the reboot type required for pending operations do not match.
1687