Reference Guide
Severity Severity 2 (Warning)
No alerts are applicable for this message
STOR075
Message The operation cannot be performed because the enclosure configuration mode
(Split or Unified) change request is pending.
Detailed
Description
The requested operation could not be completed because there is an operation
pending to change the enclosure configuration mode (Split or Unified). This
operation is exclusive because it involves changing the RAID backplane topology.
Recommended
Response
Action
Do one of the following: 1) Create a job to complete the pending enclosure mode
change request operation, allow the job to complete, restart the server, and then
retry the operation. 2) Cancel any pending operations on the RAID controller, and
then retry the operation.
Category Configuration (STOR = Storage)
Severity Severity 2 (Warning)
No alerts are applicable for this message
STOR076
Message Enclosure configuration mode (Split/Unified) cannot be changed because there are
already pending operations.
Detailed
Description
The requested operation could not be completed because at least one other
pending operation was found on the RAID controller. This operation needs
exclusivity because it involves changing RAID backplane topology.
Recommended
Response
Action
Do one of the following: 1) Create a job to complete the pending operations, allow
the job to complete, and then retry the operation. 2) Cancel any pending
operations on the RAID controller, and then retry the operation.
Category Configuration (STOR = Storage)
Severity Severity 2 (Warning)
No alerts are applicable for this message
STOR077
Message Unable to change Patrol Read State since Patrol Read Mode is not set to Manual.
Detailed
Description
A Patrol Read State change operation cannot be performed if the Patrol Read Mode
is not set to Manual.
Recommended
Response
Action
Change the Patrol Read Mode to Manual before performing a Patrol Read State
change operation.